Description
A damp patch on a chimney breast is one of the most misdiagnosed problems there is. Most people go straight for the lead flashing, pay to have it all renewed, and then find the damp is still there a few months later. Roger joins the team from Wheatley Plastering on a top-floor chimney breast where the cause could be penetrating damp through the stack, condensation inside a disused flue, or simply moisture condensing on a cold wall at the top of the house.
Rather than guess, the job takes care of all three. Stormdry Max goes on the brickwork, Dryrods go in where the damp-proof course should have been, TS-PLUS tanking slurry holds back both damp and soot staining, and then the wall gets Dryzone Renovation Insulating Plaster with a Hi-Lime finish to warm the surface and buffer any airborne moisture.
PRODUCTS USED
🔗 Stormdry Max
https://go.skill-builder.uk/stormdrymax
🔗 Dryrod Damp Proofing Rods
https://go.skill-builder.uk/dryrods
🔗 Drybase Bondaid Plus SBR
https://go.skill-builder.uk/bondaid
🔗 Drybase TS-PLUS Tanking Slurry Kit
https://go.skill-builder.uk/drybase-ts-plus-kit
🔗 Dryzone Renovation Insulating Plaster
https://go.skill-builder.uk/dryzone-renovation-plasters
🔗 Dryzone Hi-Lime Finishing Plaster
https://go.skill-builder.uk/hi-lime-plaster
KEY TAKEAWAYS
- The flashing is the usual suspect but very often it isn't the cause, so check the loft for water stains running down the brickwork before you spend money renewing it.
- Warm air rising up a disused flue condenses at the point where the chimney enters the unheated part of the building, which is why the loft is a good place to start looking.
- Older chimney stacks were built without a damp proof course, so water can track straight down through the brickwork into the room below.
- Tanking slurry does two jobs on a chimney breast: it holds the damp back and it stops soot staining bleeding through onto the finished wall.
- Insulating plaster warms the wall surface, which lets it absorb a bit of condensation as a buffer and release it again as the room dries out.
- You don't have to finish in lime. Ordinary multi finish will do, but lime is breathable and the white finish looks done, so the customer isn't asking when you're coming back to paint it.
CHAPTERS
0:00 A very common problem
0:31 Condensation in a disused flue
0:54 What to look for in the loft
1:13 Stormdry Max and Dryrods
1:48 The belt and braces plan
3:55 TS-PLUS tanking slurry
4:29 The magic ingredient
6:15 48 hours to set
6:34 Lime or multi finish
6:56 Why a white finish keeps the customer happy
#DampProofing #ChimneyBreast #Plastering #Renovation #SkillBuilder
====================
👇 SUPPORT SB - BECOME A MEMBER
https://www.youtube.com/channel/UC9GdB6vG6m6cDAwrTAWXgyg/join
📪 JOIN OUR NEWSLETTER
https://skill-builder.uk/signup
🛒 SEE OUR FAVOURITES ON AMAZON
https://www.amazon.co.uk/shop/skillbuilder
🎧 LISTEN TO OUR PODCAST
https://blubrry.com/skillbuilder/subscribe
🎬 OUR VIDEO LIBRARY
https://www.youtube.com/@SkillBuilder/videos
🔗 SEE EVERYTHING SB ON LINKTREE
https://linktr.ee/skillbuilder
https://www.facebook.com/skillbuilderchannel
https://www.tiktok.com/@skillbuilder
https://www.instagram.com/skill_builder
(As an Amazon Associate, we earn from qualifying purchases)
====================
OUR FAVOURITE CHARITIES
👷 BAND OF BUILDERS
https://bandofbuilders.org
⛯ THE LIGHTHOUSE CHARITY
https://lighthousecharity.org
💧 CHARITY WATER
https://www.charitywater.org